Test ID NBLD0463 Eosinophil Smear, Non-Nasal
AKA
Urine for Eosinophils
Specimen Type/Requirements
Collect a random urine specimen in a clean, dry, screw-top container; or 8 mL conical yellow-top tube no preservatives; or 8 mL conical red/yellow jungle-top tube with chlorhexidine preservative (6 mL minimum).
Preparing Sediment and Cytospin Slides:
- Centrifuge urine in Kova tube or other tube to obtain urine sediment
- Prepare cytospin slides from urine sediment
- Utilize time and speed in cytocentrifuge that is used for body fluid specimens in current facility
- Albumin should be used to make cytospins
- Allow smears to air dry prior to shipping
Specimen Volume
Preferred Volume | 8-12 mL urine |
Minimum Volume | 1.0 mL urine |
Stability/Transport
Room Temperature |
2 hours (unpreserved) 48 hours (preserved) |
Preferred for Transport >8 hours |
Refrigerated |
8 hours (unpreserved) |
Preferred for Transport <8 hours |
Frozen | N/A |
Performed Test Frequency
Monday through Sunday
Methodology
Light microscopy
Performing Lab
Sanford Laboratories Fargo- Core Lab
CPT
89190