Sign in →

Test ID NBLD0332 Sperm Count Post Vasectomy

Specimen Type/Requirements

Sterile Container - Semen

 

Test is not affected by hemolysis or lipemia.

Specimen Volume

 Preferred Volume     Entire semen sample  
 Minimum Volume     Entire semen sample   

 

Performed Test Frequency

Sioux Falls: Monday through Friday

Bemidji: Monday through Friday (Collections need be received by 4:00 pm on Friday.)

Bismarck: Monday through Sunday

Report Available

Same Day

Methodology

Microscopy

Performing Lab

Sanford Laboratories Sioux Falls, Bismarck and Bemidji

CPT

89321

Interface Build Information

Result Code  Result Code Description 
5746 Sperm Post Vas

 

AKA

Vasectomy, Semen, Post Vas

 

Stability/Transport

 Room Temperature     1 hour     Body temperature is preferred for transport   
 Refrigerated     Not Acceptable     
 Frozen     Not Acceptable     

Additional Information

Collect entire semen sample in a clean container.
Transport to the lab IMMEDIATELY, keeping specimen at body temperature during transport.
The specimen must be brought to the testing laboratory within 72 hours of collection.  Specimens received in the lab more than 1 hour following collection will only be evaluated for the presence or absence of sperm and will NOT be evaluated for motility.