Test ID NBLD0204 PH Body Fluid

Specimen Type/Requirements

Sterile Container - Body Fluid (specimens collected on site at SMC may be submitted in a sterile
container)

Red top (Serum w/out gel) tube - Body Fluid

 

Note: Specimens referred to the performing lab should be transferred to a small sealed container to minimize exposure to air. Transfer container must be at least half full of specimen to minimize exposure to air.  Use smallest transfer container available.

 

Test is not affected by hemolysis or lipemia.

Specimen Volume

 Preferred Volume     3.0 mL   

 

Performed Test Frequency

Monday through Sunday

Methodology

Blood Gas Analyzer for serous fluids pH paper for non-serous fluids

Performing Lab

Sanford Laboratories Sioux Falls

CPT

83986

Stability/Transport

 Room Temperature     1 hour     
 Refrigerated     4 days     Preferred for transport   